For now, I'd like to start a discussion on what all the LAVA members think of the changes and additions. I will post a link here when it's ready for online consumption. A CLED demonstrates proficiency and experience in analyzing requirements, designing,I did a presentation at NIWeek 2013 on the new user event features in LabVIEW 2013. The National Instruments Certified LabVIEW Embedded Systems Developer (CLED) is an expert level exam designed to distinguish LabVIEW certified professionals experienced in embedded control and monitoring applications.
Labview 2013 Requirements Mac OSX And LinuxNew - Event Inspector Window (you're gonna love this!) Requirements LabVIEW 2013 or later OPC Data Access 3.00 Issues NA Support for Mac OSX and Linux is available upon request.To summarize, here is what was changed, added:OPC DA Client for LabVIEW Toolkit Revision History Release Date: 16 January, 2017 Version: 1.1.0.27 Functionality added NA Updates and Bug fixes Corrected issue regarding tag read references close in. Minimum Hardware: 2.3 GHz CPU and 4 GB memory Operating System: Windows (XP or later). Support for earlier versions of LabVIEW is available upon request. You are using later versions (i am now on LabVIEW 2013) then look for an update.Desktop LabVIEW Host Platform (Basic and MultiClient Client Mapping) LabVIEW 2013 32-bit or later.![]() Labview 2013 Requirements How To Make OurLabview 2013 Requirements Code Better WithSliders generate thousands of events which overfed the consuming hardware actor. Let's figure out how to make our code better with all this new cool stuff.Did a project in 2007 where a slider was linked to the amplitude of an analog output. I know a lot of you are using user events as the main communication mechanism for your processes and modules.
So I would only set the analog out after the 100s of value changes had stopped for 0ms. The timeout case only gets executed when there are no other events in the event queue. Then in the timeout case I would perform the analog output, then set the boolean in the shift register back to false. This boolean would set the event structure timeout to 0ms. Maybe this challenge would be better handled today by flushing specific events instead of managing registration?I agree that this can be a place where the Flush can be used, but my work around was when the slider had a value change all it did was set a boolean true in a shift register. There were other requirements with this method which were necessary to ensure that I got the latest value when the operator was finished dragging. Unity android replace play services games versionThe timeout case only gets executed when there are no other events in the event queue. Then in the timeout case I would perform the analog output, then set the boolean in the shift register back to false. This boolean would set the event structure timeout to 0ms. Edited Augby hooovahhI agree that this can be a place where the Flush can be used, but my work around was when the slider had a value change all it did was set a boolean true in a shift register. The problem we are facing is that the ActiveX interface does not support events. This can be handled in the timeout case, or in a separate consumer loop depending on the requirements.We have a 3rd party application that can talk to an arbitrary LabVIEW VI (or exe) via ActiveX and can both change and read the controls on the VI (or exe). Another option is to use a size limited queue used with the lossy enqueue primitive. How can you be sure that the last element isn't already in the event queue, meaning that flushing will remove the most important element you actually want to handle.Letting the timeout case handle the last event can be very neat, and I use this very often in small UIs. This would reduce the number of analog output commands from 100s to on the order of 10 or so and it would always set the last value.I don't think flushing events would solve this, e.g. ![]()
0 Comments
Leave a Reply. |
AuthorGlenn ArchivesCategories |